Automatic Transfer Switch controllers (ATS)

AT1000 series controller is an automatic transfer switch controller with user friendly interface and controls. In auto mode, ATS controller monitors voltage and frequency of incoming AC supply from two different sources namely S1 (Mains) and S2 (Genset). In event of S1 failure, it issues a start command to S2 and transfers load on it. When S1 is available again, the controller restores the load back to S1.

In manual mode, the controller allows the operator to manually control the transfer of load using transfer keys available on front facia. Various timers available ensure the precise switching among sources by distinguishing between actual failure and momentary transients.

AT1000 series controller is provided with immediate phase reversal detection feature which allows user to configure the action

  • It is equipped with a USB port for communication with PC via configuration utility
  • Backlit and full graphics LCD with power saving feature provides prolonged battery life

FEATURES

  • Auto transfer switch controller with 8 digital inputs, 1 analog input (can also be used as digital input, if configured) and 10 digital outputs
  • Senses genset output voltage and frequency precisely for 1-ph/3-ph
  • Incremental counters for engine start, engine trips, engine run hours, kWh, kVAh, kVArh etc.
  • Monitors 1-ph/3-ph voltage, frequency, power factor and load current for genset
  • Monitors 1-ph/3-ph voltage, frequency and load current for mains
  • Measures mains kW, kVA, kVAr, kWh, kVAh, kVArh, etc.
  • Auto, Manual and Auto Exercise mode (16 events) for 1-ph/3-ph genset
  • Immediate phase reversal detection with configurable action
  • Backlit and full graphics LCD with power saving feature (Deep Sleep mode) provides prolonged battery life
  • Versatile software capable of saving "events" during operation (event log for 100 events with Real Time Clock (RTC) stamps and engine run hour information)
  • PC connectivity via USB port and RS485 via MODBUS
  • Communicates with PC via configuration utility (Smart Config) through a USB port
  • Access to each parameter through configuration utility (Smart Config) or control keys

PRODUCT COMPARISON

# Feature SEDEMAC AT1000 Deep Sea
DSE 331
Deep Sea
DSE335
ComAp InteliATS NT PWR
0 Overall size 139 x 114 mm2 180 x 116 mm2 240 x 181 mm2 180 x 120 mm2
1 Configurable digital inputs 9 4 12 7
2 Configurable DC output 10 4+4*
(*Potential Free Configurable outputs)
6+6*
(*Potential Free Configurable outputs)
7
3 Storage of multiple profiles (parameter sets) 10 X X X
4 Three phase voltage monitoring Y Y Y Y
5 Three Phase power monitoring Y Y Y Y
6 Mains and genset contactor control, load inhibit, start inhibit, license free PC software Y Y Y Y
7 Fully graphics LCD display Y Y Y Y
8 Phase reversal detection Y X Y X
9 Remote communication via RS485-MODBUS Y X Y Y
10 LED indicators for keypad Y X Y Y

FAQs

What is SEDEMAC’s CR-ECU offering?

CR-ECU is an electrically operated injection system for LCVs, MCVs and HCVs, designed to help meet the emission norms.

What is unique about SEDEMAC's CR-ECU solution?
Who can be SEDEMAC’s customers for CR-ECU?
Are these ECUs BSVI compliant?

SPECIFICATIONS

Environmental Specifications
  • Operating / Storage Temperature: -20°C to 65°C / -30°C to 70°C, as per IEC 60068-2-1, 2
  • Vibration: 2G in X,Y,Z axis for 8-500 Hz, as per IEC 60068-2-6
  • Humidity: 0 to 95% RH, as per IEC 60068-2-78
  • EMI/EMC: Compliance as per IEC 61000-6-2, 4
  • Power Supply: 8V - 32V continuous; power transient as per ISO 7637-2
  • Ingress Protection: IP65 for front face with optional gasket, as per IEC 60529
  • Shock: 15 g for 11 mS, compliance as per IEC 60068-2-27
Technical Specifications
  • Maximun Standby Current: ~0.08A @ 12V or 24V DC
  • Crank-Start Dropout Survival Period: 50 mS for a drop from 12V DC
  • Digital Output: 10 x 0.75A high-side drivers configurable outputs
  • Digital Input: 8 switch-to-ground configurable inputs
  • Analog Input: 1 resistive input (10Ω - 1000Ω) configurable as shelter temperature or digital input.
  • Mains / Genset Voltage Measurement: 20V-350V AC RMS @ 5-75 Hz for Ph to N
  • Load Current Measurement: 0A - 5A AC RMS for current transformer (CT) secondary
  • Dimensions:
    External Dimensions: 139 mm x 114 mm x 37.5 mm
    Mounting Panel Cut: 118 mm x 93 mm